Capacity | Cooling / Heating | 2,7 (0,7–5,0) / 3,5 (0,7–5,5) | kW |
Power Supply | Into Outdoor Unit | 220 – 240 / 1 / 50 | V / Ph / Hz |
Power Input | Cooling / Heating | 0,55 / 0,75 | kW |
Rated Power Input | Cooling / Heating | 2,4 | kW |
Power Current | Cooling / Heating | 3,6 / 4,7 | A |
Rated Power Current | Cooling / Heating | 8,0 | A |
Energy class | Cooling / Heating (A, W, C) * | A+++ / (A+++, A+++, A+) | – |
Pdesign | Cooling / Heating | 2,7 / 3,5 | kW |
SEER / SCOP | – | 8,5 / 5,1 | W / W |
Air Flow | Indoor Unit | 800 / 720 / 570 / 620 / 560 / 500 / 450 | m3 / h |
Air Flow | Outdoor Unit | 2400 | m3 / h |
Sound Pressure Level at 1 m | Indoor Unit | 43 / 41 / 38 / 36 / 33 / 31 / 18 | dB(A) |
Sound Pressure Level at 1 m | Outdoor Unit | 53 | dB(A) |
Sound Power Level | Indoor unit | 58 / 51 / 48 / 46 / 43 / 41 / 28 | dB(A) |
Sound Power Level | Outdoor unit | 62 | dB(A) |
Dehumidifying Volume | – | 0,8 | l / h |
Refrigerant / Charge / Eq. CO2 | – | R32 / 1,0 / 0,67 | type / kg / t |
Additional Refrigerant | – | 16 | g / m |
Refrigerant Liquid Pipe | Diameter | 1/4 / 6 | inch / mm |
Refrigerant Gas Pipe | Diameter | 3/8 / 9,5 | inch / mm |
Max pipe length without additional refrigerant | – | 5 | m |
Min. / Max. Pipe Length | – | 3 / 15 | m |
Max. Elevation | – | 10 | m |
Dimension (w x h x d) | Indoor Unit | 996 × 301 × 225 | mm |
Dimension (w x h x d) | Outdoor Unit | 899 x 596 x 378 | mm |
Package (w x h x d) | Indoor Unit | 1060 x 380 x 322 | mm |
Package (w x h x d) | Outdoor Unit | 948 x 420 x 645 | mm |
Package volume | Indoor unit | 0,130 | m3 |
Package volume | Outdoor unit | 0,257 | m3 |
Net / Gross Weight | Indoor Unit | 13,0 / 16,0 | kg |
Net / Gross Weight | Outdoor Unit | 44,5 / 47,5 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Operating Temperature Range | Cooling | -18 ~ 52 | °C |
Operating Temperature Range | Heating | – 30 ~ 24 | °C |
Capacity | Cooling / Heating | 3,6 (0,9–5,0) / 4,2 (0,9–7,2) | kW |
Power Supply | Into Outdoor Unit | 220 – 240 / 1 / 50 | V / Ph / Hz |
Power Input | Cooling / Heating | 0,84 / 0,95 | kW |
Rated Power Input | Cooling / Heating | 2,6 | kW |
Power Current | Cooling / Heating | 5,1 / 5,7 | A |
Rated Power Current | Cooling / Heating | 8,2 | A |
Energy class | Cooling / Heating (A, W, C) * | A+++ / (A+++, A+++, A+) | – |
SEER / SCOP | – | 8,5 / 5,1 | W / W |
Air Flow | Indoor Unit | 800 / 730 / 680 / 630 / 580 / 530 / 430 | m3 / h |
Air Flow | Outdoor Unit | 2400 | m3 / h |
Sound Pressure Level at 1 m | Indoor Unit | 46 / 43 / 41 / 38 / 36 / 34 / 21 | dB(A) |
Sound Pressure Level at 1 m | Outdoor Unit | 54 | dB(A) |
Dehumidifying Volume | – | 1,4 | l / h |
Refrigerant / Charge / Eq. CO2 | – | R32 / 1,0 / 0,67 | type / kg / t |
Additional Refrigerant | – | 20 | g / m |
Refrigerant Liquid Pipe | Diameter | 1/4 / 6 | inch / mm |
Refrigerant Gas Pipe | Diameter | 3/8 / 9,5 | inch / mm |
Max pipe length without additional refrigerant | – | 5 | m |
Min. / Max. Pipe Length | – | 3 / 20 | m |
Max. Elevation | – | 10 | m |
Dimension (w x h x d) | Indoor Unit | 996 × 301 × 225 | mm |
Dimension (w x h x d) | Outdoor Unit | 899 x 596 x 378 | mm |
Package (w x h x d) | Indoor Unit | 1060 x 380 x 322 | mm |
Package (w x h x d) | Outdoor Unit | 948 x 420 x 645 | mm |
Net / Gross Weight | Indoor Unit | 13,5 / 16,5 | kg |
Net / Gross Weight | Outdoor Unit | 45,5 / 48,5 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Operating Temperature Range | Cooling | -18 ~ 54 | °C |
Operating Temperature Range | Heating | – 30 ~ 24 | °C |
Capacity | Cooling / Heating | 5,3 (1,2–7,2) / 5,6 (1,2–9,2) | kW |
Power Supply | Into Outdoor Unit | 220 – 240 / 1 / 50 | V / Ph / Hz |
Power Input | Cooling / Heating | 1,32 / 1,32 | kW |
Rated Power Input | Cooling / Heating | 3,3 | kW |
Power Current | Cooling / Heating | 5,9 / 5,9 | A |
Rated Power Current | Cooling / Heating | 13,0 | A |
Energy class | Cooling / Heating (A, W, C) * | A++ / (A+, A+++, A) | – |
Pdesign | Cooling / Heating | – / 6,3 | kW |
SEER / SCOP | – | 6,6 / 4,4 | W / W |
Air Flow | Indoor Unit | 1200 / 1150 / 1050 / 950 / 850 / 780 / 600 | m3 / h |
Air Flow | Outdoor Unit | 4000 | m3 / h |
Sound Pressure Level at 1 m | Indoor Unit | 48 / 45 / 43 / 40 / 37 / 35 / 33 | dB(A) |
Sound Pressure Level at 1 m | Outdoor Unit | 56 | dB(A) |
Sound Power Level | Indoor unit | 60 / 57 / 55 / 52 / 49 / 47 / 45 | dB(A) |
Sound Power Level | Outdoor unit | 63 | dB(A) |
Dehumidifying Volume | – | 1,8 | l / h |
Refrigerant / Charge / Eq. CO2 | – | R32 / 1,50 / 1,01 | type / kg / t |
Additional Refrigerant | – | 40 | g / m |
Refrigerant Liquid Pipe | Diameter | 1/4 / 6 | inch / mm |
Refrigerant Gas Pipe | Diameter | 5/8 / 16 | inch / mm |
Max pipe length without additional refrigerant | – | 5 | m |
Min. / Max. Pipe Length | – | 3 / 40 | m |
Max. Elevation | – | 20 | m |
Dimension (w x h x d) | Indoor Unit | 1101 × 327 × 249 | mm |
Dimension (w x h x d) | Outdoor Unit | 1003 x 790 x 427 | mm |
Package (w x h x d) | Indoor Unit | 1167 x 405 x 354 | mm |
Package (w x h x d) | Outdoor Unit | 1083 x 488 x 855 | mm |
Package volume | Indoor unit | 0,167 | m3 |
Package volume | Outdoor unit | 0,452 | m3 |
Net / Gross Weight | Indoor Unit | 16,5 / 20,0 | kg |
Net / Gross Weight | Outdoor Unit | 62,5 / 67,5 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Operating Temperature Range | Cooling | -18 ~ 52 | °C |
Operating Temperature Range | Heating | – 30 ~ 24 | °C |
Power Supply | Into Outdoor Unit | 220 – 240 / 1 / 50 | V / Ph / Hz |
Power Input | Cooling / Heating | 1,85 / 1,75 | kW |
Rated Power Input | Cooling / Heating | 3,8 | kW |
Power Current | Cooling / Heating | 11,0 / 11,0 | A |
Rated Power Current | Cooling / Heating | 16,4 | A |
SEER / SCOP | – | 6,5 / 4,1 | W / W |
Air Flow | Indoor Unit | 1200 / 1050 / 950 / 900 / 850 / 800 / 750 | m3 / h |
Air Flow | Outdoor Unit | 4000 | m3 / h |
Sound Pressure Level at 1 m | Indoor Unit | 50 / 46 / 43 / 41 / 39 / 37 / 35 | dB(A) |
Sound Pressure Level at 1 m | Outdoor Unit | 58 | dB(A) |
Dehumidifying Volume | – | 2,0 | l / h |
Refrigerant / Charge / Eq. CO2 | – | R32 / 2,0 / 1,35 | type / kg / t |
Additional Refrigerant | – | 50 | g / m |
Refrigerant Liquid Pipe | Diameter | 1/4 / 6 | inch / mm |
Refrigerant Gas Pipe | Diameter | 5/8 / 16 | inch / mm |
Max pipe length without additional refrigerant | – | 7,5 | m |
Min. / Max. Pipe Length | – | 3 / 50 | m |
Max. Elevation | – | 30 | m |
Dimension (w x h x d) | Indoor Unit | 1101 × 327 × 249 | mm |
Dimension (w x h x d) | Outdoor Unit | 1003 x 790 x 427 | mm |
Package (w x h x d) | Indoor Unit | 1167 x 405 x 354 | mm |
Package (w x h x d) | Outdoor Unit | 1083 x 488 x 855 | mm |
Net / Gross Weight | Indoor Unit | 16,5 / 20,0 | kg |
Net / Gross Weight | Outdoor Unit | 65,0 / 70,0 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Operating Temperature Range | Cooling | -18 ~ 52 | °C |
Operating Temperature Range | Heating | – 30 ~ 24 | °C |
Energy class | Cooling / Heating (A, W, C) * | A++ / (A+, A+++, A) | – |
Capacity | Cooling / Heating | 2,7 (0,7–5,0) / 3,5 (0,7–5,5) | kW |
Power Supply | Into Outdoor Unit | 220 – 240 / 1 / 50 | V / Ph / Hz |
Power Input | Cooling / Heating | 0,55 / 0,75 | kW |
Rated Power Input | Cooling / Heating | 2,4 | kW |
Power Current | Cooling / Heating | 3,6 / 4,7 | A |
Rated Power Current | Cooling / Heating | 8,0 | A |
Energy class | Cooling / Heating (A, W, C) * | A+++ / (A+++, A+++, A+) | – |
Pdesign | Cooling / Heating | 2,7 / 3,5 | kW |
SEER / SCOP | – | 8,5 / 5,1 | W / W |
Air Flow | Indoor Unit | 800 / 720 / 570 / 620 / 560 / 500 / 450 | m3 / h |
Air Flow | Outdoor Unit | 2400 | m3 / h |
Sound Pressure Level at 1 m | Indoor Unit | 43 / 41 / 38 / 36 / 33 / 31 / 18 | dB(A) |
Sound Pressure Level at 1 m | Outdoor Unit | 53 | dB(A) |
Sound Power Level | Indoor unit | 58 / 51 / 48 / 46 / 43 / 41 / 28 | dB(A) |
Sound Power Level | Outdoor unit | 62 | dB(A) |
Dehumidifying Volume | – | 0,8 | l / h |
Refrigerant / Charge / Eq. CO2 | – | R32 / 1,0 / 0,67 | type / kg / t |
Additional Refrigerant | – | 16 | g / m |
Refrigerant Liquid Pipe | Diameter | 1/4 / 6 | inch / mm |
Refrigerant Gas Pipe | Diameter | 3/8 / 9,5 | inch / mm |
Max pipe length without additional refrigerant | – | 5 | m |
Min. / Max. Pipe Length | – | 3 / 15 | m |
Max. Elevation | – | 10 | m |
Dimension (w x h x d) | Indoor Unit | 996 × 301 × 225 | mm |
Dimension (w x h x d) | Outdoor Unit | 899 x 596 x 378 | mm |
Package (w x h x d) | Indoor Unit | 1060 x 380 x 322 | mm |
Package (w x h x d) | Outdoor Unit | 948 x 420 x 645 | mm |
Package volume | Indoor unit | 0,130 | m3 |
Package volume | Outdoor unit | 0,257 | m3 |
Net / Gross Weight | Indoor Unit | 13,0 / 16,0 | kg |
Net / Gross Weight | Outdoor Unit | 44,5 / 47,5 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Operating Temperature Range | Cooling | -18 ~ 52 | °C |
Operating Temperature Range | Heating | – 30 ~ 24 | °C |
Capacity | Cooling / Heating | 5,3 (1,2–7,2) / 5,6 (1,2–9,2) | kW |
Power Supply | Into Outdoor Unit | 220 – 240 / 1 / 50 | V / Ph / Hz |
Power Input | Cooling / Heating | 1,32 / 1,32 | kW |
Rated Power Input | Cooling / Heating | 3,3 | kW |
Power Current | Cooling / Heating | 5,9 / 5,9 | A |
Rated Power Current | Cooling / Heating | 13,0 | A |
Energy class | Cooling / Heating (A, W, C) * | A++ / (A+, A+++, A) | – |
Pdesign | Cooling / Heating | – / 6,3 | kW |
SEER / SCOP | – | 6,6 / 4,4 | W / W |
Air Flow | Indoor Unit | 1200 / 1150 / 1050 / 950 / 850 / 780 / 600 | m3 / h |
Air Flow | Outdoor Unit | 4000 | m3 / h |
Sound Pressure Level at 1 m | Indoor Unit | 48 / 45 / 43 / 40 / 37 / 35 / 33 | dB(A) |
Sound Pressure Level at 1 m | Outdoor Unit | 56 | dB(A) |
Sound Power Level | Indoor unit | 60 / 57 / 55 / 52 / 49 / 47 / 45 | dB(A) |
Sound Power Level | Outdoor unit | 63 | dB(A) |
Dehumidifying Volume | – | 1,8 | l / h |
Refrigerant / Charge / Eq. CO2 | – | R32 / 1,50 / 1,01 | type / kg / t |
Additional Refrigerant | – | 40 | g / m |
Refrigerant Liquid Pipe | Diameter | 1/4 / 6 | inch / mm |
Refrigerant Gas Pipe | Diameter | 5/8 / 16 | inch / mm |
Max pipe length without additional refrigerant | – | 5 | m |
Min. / Max. Pipe Length | – | 3 / 40 | m |
Max. Elevation | – | 20 | m |
Dimension (w x h x d) | Indoor Unit | 1101 × 327 × 249 | mm |
Dimension (w x h x d) | Outdoor Unit | 1003 x 790 x 427 | mm |
Package (w x h x d) | Indoor Unit | 1167 x 405 x 354 | mm |
Package (w x h x d) | Outdoor Unit | 1083 x 488 x 855 | mm |
Package volume | Indoor unit | 0,167 | m3 |
Package volume | Outdoor unit | 0,452 | m3 |
Net / Gross Weight | Indoor Unit | 16,5 / 20,0 | kg |
Net / Gross Weight | Outdoor Unit | 62,5 / 67,5 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Operating Temperature Range | Cooling | -18 ~ 52 | °C |
Operating Temperature Range | Heating | – 30 ~ 24 | °C |