CONSOLE SERIES

Console air conditioning units offer new installation options thanks to their thin profile. They can be installed just above the floor like ordinary radiators. The design of these split floor-ceiling AC units allows optimizing the operation thanks to the air outlets in two directions. In the heating mode, you can easily select the lower air outlet, which evokes the feeling of underfloor heating.

Additional information

Product Description

    CapacityCooling / Heating2,7 (0,7–3,4) / 2,9 (0,6–3,5)kW
    Power SupplyInto Outdoor Unit220 – 240 / 1 / 50V / Ph / Hz
    Power InputCooling / Heating0,72 / 0,73kW
    Rated Power InputCooling / Heating1,35kW
    Power CurrentCooling / Heating3,5 / 3,6A
    Rated Power CurrentCooling / Heating6,0A
    SEER / SCOP7,2 / 4,0W / W
    Energy classCooling / Heating (A, W, C) *A++ / (A+, A+++, -)
    Air FlowIndoor Unit500 / 430 / 410 / 370 / 330 / 280 / 250m3 / h
    Air FlowOutdoor Unit1600m3 / h
    Sound Pressure Level at 1 mIndoor Unit39 / 36 / 33 / 31 / 29 / 26 / 23dB(A)
    Sound Pressure Level at 1 mOutdoor Unit49dB(A)
    Sound Power LevelIndoor unit50 / 48 / 45 / 44 / 42 / 38 / 34dB(A)
    Sound Power LevelOutdoor unit60dB(A)
    Dehumidifying Volume0,8l / h
    Refrigerant / Charge / Eq. CO2R32 / 0,55 / 0,37type / kg / t
    Additional Refrigerant16g / m
    Refrigerant Liquid PipeDiameter1/4 / 6inch / mm
    Refrigerant Gas PipeDiameter3/8 / 9,5inch / mm
    Max pipe length without additional refrigerant5m
    Min. / Max. Pipe Length3 / 20m
    Max. Elevation10m
    Dimension (w x h x d)Indoor Unit700 x 600 x 215mm
    Dimension (w x h x d)Outdoor Unit782 x 540 x 320mm
    Package (w x h x d)Indoor Unit785 x 682 x 280mm
    Package (w x h x d)Outdoor Unit823 x 595 x 358mm
    Package volumeIndoor unit0,153m3
    Package volumeOutdoor unit0,175m3
    Net / Gross WeightIndoor Unit15,5 / 18,5kg
    Net / Gross WeightOutdoor Unit27,5 / 30,0kg
    Set Temperature range16 ~ 30°C
    Operating Temperature RangeCooling-15 ~ 43°C
    Operating Temperature RangeHeating– 22 ~ 24°C
    CapacityCooling / Heating3,5 (0,8–4,4) / 3,8 (1,1–4,4)kW
    Power SupplyInto Outdoor Unit220 – 240 / 1 / 50V / Ph / Hz
    Power InputCooling / Heating1,00 / 0,96kW
    Rated Power InputCooling / Heating1,5kW
    Power CurrentCooling / Heating4,5 / 4,3A
    Rated Power CurrentCooling / Heating6,7A
    SEER / SCOP7,0 / 4,1W / W
    Energy classCooling / Heating (A, W, C) *A++ / (A+, A+++, -)
    Air FlowIndoor Unit600 / 520 / 480 / 440 / 400 / 360 / 280m3 / h
    Air FlowOutdoor Unit2200m3 / h
    Sound Pressure Level at 1 mIndoor Unit42 / 40 / 38 / 36 / 34 / 31 / 25dB(A)
    Sound Pressure Level at 1 mOutdoor Unit52dB(A)
    Sound Power LevelIndoor unit52 / 50 / 48 / 46 / 43 / 39 / 35dB(A)
    Sound Power LevelOutdoor unit62dB(A)
    Dehumidifying Volume1,2l / h
    Refrigerant / Charge / Eq. CO2R32 / 0,75 / 0,51type / kg / t
    Additional Refrigerant16g / m
    Refrigerant Liquid PipeDiameter1/4 / 6inch / mm
    Refrigerant Gas PipeDiameter3/8 / 9,5inch / mm
    Max pipe length without additional refrigerant5m
    Min. / Max. Pipe Length3 / 20m
    Max. Elevation10m
    Dimension (w x h x d)Indoor Unit700 x 600 x 215mm
    Dimension (w x h x d)Outdoor Unit848 x 596 x 320mm
    Package (w x h x d)Indoor Unit785 x 682 x 280mm
    Package (w x h x d)Outdoor Unit881 x 645 x 363mm
    Package volumeIndoor unit0,150m3
    Package volumeOutdoor unit0,206m3
    Net / Gross WeightIndoor Unit15,5 / 18,5kg
    Net / Gross WeightOutdoor Unit30,5 / 33,5kg
    Set Temperature range16 ~ 30°C
    Operating Temperature RangeCooling-15 ~ 43°C
    Operating Temperature RangeHeating– 22 ~ 24°C
    CapacityCooling / Heating5,2 (1,3–6,6) / 5,3 (1,1–6,8)kW
    Power SupplyInto Outdoor Unit220 – 240 / 1 / 50V / Ph / Hz
    Power InputCooling / Heating1,55 / 1,50kW
    Rated Power InputCooling / Heating2,5kW
    Power CurrentCooling / Heating7,1 / 6,7A
    Rated Power CurrentCooling / Heating10,9A
    SEER / SCOP6,6 / 4,1W / W
    Energy classCooling / Heating (A, W, C) *A++ / (A+, A+++, -)
    Air FlowIndoor Unit700 / 650 / 580 / 520 / 460 / 410 / 320m3 / h
    Air FlowOutdoor Unit3200m3 / h
    Sound Pressure Level at 1 mIndoor Unit47 / 45 / 43 / 41 / 38 / 37 / 32dB(A)
    Sound Pressure Level at 1 mOutdoor Unit57dB(A)
    Sound Power LevelIndoor unit57 / 55 / 53 / 51 / 48 / 47 / 42dB(A)
    Sound Power LevelOutdoor unit65dB(A)
    Dehumidifying Volume1,8l / h
    Refrigerant / Charge / Eq. CO2R32 / 0,95 / 0,64type / kg / t
    Additional Refrigerant20g / m
    Refrigerant Liquid PipeDiameter1/4 / 6inch / mm
    Refrigerant Gas PipeDiameter1/2 / 12inch / mm
    Max pipe length without additional refrigerant5m
    Min. / Max. Pipe Length3 / 25m
    Max. Elevation10m
    Dimension (w x h x d)Indoor Unit700 x 600 x 215mm
    Dimension (w x h x d)Outdoor Unit965 x 700 x 396mm
    Package (w x h x d)Indoor Unit785 x 682 x 280mm
    Package (w x h x d)Outdoor Unit1026 x 455 x 735mm
    Package volumeIndoor unit0,150m3
    Package volumeOutdoor unit0,352m3
    Net / Gross WeightIndoor Unit15,5 / 18,5kg
    Net / Gross WeightOutdoor Unit46,0 / 50,5kg
    Set Temperature range16 ~ 30°C
    Operating Temperature RangeCooling-15 ~ 43°C
    Operating Temperature RangeHeating– 22 ~ 24°C