Capacity | Cooling / Heating | 2,7 (0,7–3,4) / 2,9 (0,6–3,5) | kW |
Power Supply | Into Outdoor Unit | 220 – 240 / 1 / 50 | V / Ph / Hz |
Power Input | Cooling / Heating | 0,72 / 0,73 | kW |
Rated Power Input | Cooling / Heating | 1,35 | kW |
Power Current | Cooling / Heating | 3,5 / 3,6 | A |
Rated Power Current | Cooling / Heating | 6,0 | A |
SEER / SCOP | – | 7,2 / 4,0 | W / W |
Energy class | Cooling / Heating (A, W, C) * | A++ / (A+, A+++, -) | – |
Air Flow | Indoor Unit | 500 / 430 / 410 / 370 / 330 / 280 / 250 | m3 / h |
Air Flow | Outdoor Unit | 1600 | m3 / h |
Sound Pressure Level at 1 m | Indoor Unit | 39 / 36 / 33 / 31 / 29 / 26 / 23 | dB(A) |
Sound Pressure Level at 1 m | Outdoor Unit | 49 | dB(A) |
Sound Power Level | Indoor unit | 50 / 48 / 45 / 44 / 42 / 38 / 34 | dB(A) |
Sound Power Level | Outdoor unit | 60 | dB(A) |
Dehumidifying Volume | – | 0,8 | l / h |
Refrigerant / Charge / Eq. CO2 | – | R32 / 0,55 / 0,37 | type / kg / t |
Additional Refrigerant | – | 16 | g / m |
Refrigerant Liquid Pipe | Diameter | 1/4 / 6 | inch / mm |
Refrigerant Gas Pipe | Diameter | 3/8 / 9,5 | inch / mm |
Max pipe length without additional refrigerant | – | 5 | m |
Min. / Max. Pipe Length | – | 3 / 20 | m |
Max. Elevation | – | 10 | m |
Dimension (w x h x d) | Indoor Unit | 700 x 600 x 215 | mm |
Dimension (w x h x d) | Outdoor Unit | 782 x 540 x 320 | mm |
Package (w x h x d) | Indoor Unit | 785 x 682 x 280 | mm |
Package (w x h x d) | Outdoor Unit | 823 x 595 x 358 | mm |
Package volume | Indoor unit | 0,153 | m3 |
Package volume | Outdoor unit | 0,175 | m3 |
Net / Gross Weight | Indoor Unit | 15,5 / 18,5 | kg |
Net / Gross Weight | Outdoor Unit | 27,5 / 30,0 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Operating Temperature Range | Cooling | -15 ~ 43 | °C |
Operating Temperature Range | Heating | – 22 ~ 24 | °C |
Capacity | Cooling / Heating | 3,5 (0,8–4,4) / 3,8 (1,1–4,4) | kW |
Power Supply | Into Outdoor Unit | 220 – 240 / 1 / 50 | V / Ph / Hz |
Power Input | Cooling / Heating | 1,00 / 0,96 | kW |
Rated Power Input | Cooling / Heating | 1,5 | kW |
Power Current | Cooling / Heating | 4,5 / 4,3 | A |
Rated Power Current | Cooling / Heating | 6,7 | A |
SEER / SCOP | – | 7,0 / 4,1 | W / W |
Energy class | Cooling / Heating (A, W, C) * | A++ / (A+, A+++, -) | – |
Air Flow | Indoor Unit | 600 / 520 / 480 / 440 / 400 / 360 / 280 | m3 / h |
Air Flow | Outdoor Unit | 2200 | m3 / h |
Sound Pressure Level at 1 m | Indoor Unit | 42 / 40 / 38 / 36 / 34 / 31 / 25 | dB(A) |
Sound Pressure Level at 1 m | Outdoor Unit | 52 | dB(A) |
Sound Power Level | Indoor unit | 52 / 50 / 48 / 46 / 43 / 39 / 35 | dB(A) |
Sound Power Level | Outdoor unit | 62 | dB(A) |
Dehumidifying Volume | – | 1,2 | l / h |
Refrigerant / Charge / Eq. CO2 | – | R32 / 0,75 / 0,51 | type / kg / t |
Additional Refrigerant | – | 16 | g / m |
Refrigerant Liquid Pipe | Diameter | 1/4 / 6 | inch / mm |
Refrigerant Gas Pipe | Diameter | 3/8 / 9,5 | inch / mm |
Max pipe length without additional refrigerant | – | 5 | m |
Min. / Max. Pipe Length | – | 3 / 20 | m |
Max. Elevation | – | 10 | m |
Dimension (w x h x d) | Indoor Unit | 700 x 600 x 215 | mm |
Dimension (w x h x d) | Outdoor Unit | 848 x 596 x 320 | mm |
Package (w x h x d) | Indoor Unit | 785 x 682 x 280 | mm |
Package (w x h x d) | Outdoor Unit | 881 x 645 x 363 | mm |
Package volume | Indoor unit | 0,150 | m3 |
Package volume | Outdoor unit | 0,206 | m3 |
Net / Gross Weight | Indoor Unit | 15,5 / 18,5 | kg |
Net / Gross Weight | Outdoor Unit | 30,5 / 33,5 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Operating Temperature Range | Cooling | -15 ~ 43 | °C |
Operating Temperature Range | Heating | – 22 ~ 24 | °C |
Capacity | Cooling / Heating | 5,2 (1,3–6,6) / 5,3 (1,1–6,8) | kW |
Power Supply | Into Outdoor Unit | 220 – 240 / 1 / 50 | V / Ph / Hz |
Power Input | Cooling / Heating | 1,55 / 1,50 | kW |
Rated Power Input | Cooling / Heating | 2,5 | kW |
Power Current | Cooling / Heating | 7,1 / 6,7 | A |
Rated Power Current | Cooling / Heating | 10,9 | A |
SEER / SCOP | – | 6,6 / 4,1 | W / W |
Energy class | Cooling / Heating (A, W, C) * | A++ / (A+, A+++, -) | – |
Air Flow | Indoor Unit | 700 / 650 / 580 / 520 / 460 / 410 / 320 | m3 / h |
Air Flow | Outdoor Unit | 3200 | m3 / h |
Sound Pressure Level at 1 m | Indoor Unit | 47 / 45 / 43 / 41 / 38 / 37 / 32 | dB(A) |
Sound Pressure Level at 1 m | Outdoor Unit | 57 | dB(A) |
Sound Power Level | Indoor unit | 57 / 55 / 53 / 51 / 48 / 47 / 42 | dB(A) |
Sound Power Level | Outdoor unit | 65 | dB(A) |
Dehumidifying Volume | – | 1,8 | l / h |
Refrigerant / Charge / Eq. CO2 | – | R32 / 0,95 / 0,64 | type / kg / t |
Additional Refrigerant | – | 20 | g / m |
Refrigerant Liquid Pipe | Diameter | 1/4 / 6 | inch / mm |
Refrigerant Gas Pipe | Diameter | 1/2 / 12 | inch / mm |
Max pipe length without additional refrigerant | – | 5 | m |
Min. / Max. Pipe Length | – | 3 / 25 | m |
Max. Elevation | – | 10 | m |
Dimension (w x h x d) | Indoor Unit | 700 x 600 x 215 | mm |
Dimension (w x h x d) | Outdoor Unit | 965 x 700 x 396 | mm |
Package (w x h x d) | Indoor Unit | 785 x 682 x 280 | mm |
Package (w x h x d) | Outdoor Unit | 1026 x 455 x 735 | mm |
Package volume | Indoor unit | 0,150 | m3 |
Package volume | Outdoor unit | 0,352 | m3 |
Net / Gross Weight | Indoor Unit | 15,5 / 18,5 | kg |
Net / Gross Weight | Outdoor Unit | 46,0 / 50,5 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Operating Temperature Range | Cooling | -15 ~ 43 | °C |
Operating Temperature Range | Heating | – 22 ~ 24 | °C |