OUTDOOR UNITS

The upgraded UNI SPLIT 2 series of outdoor inverter units will adapt to the required performance. These units are available in a wide range of installed heating or cooling capacities. Thanks to the upgrade, we have managed to achieve smaller dimensions and weights of the units for easier installation. The units can be combined with the new UNI SPLIT 2 series cassette, ducted and floor-ceiling units.

Additional information

Product Description

    CapacityCooling / Heating3,5 / 4kW
    Power SupplyInto Outdoor Unit220–240 / 1 / 50/60V / Ph / Hz
    Power InputCooling / Heating1,03 / 1,00kW
    Rated Power InputCooling / Heating1,3kW
    Power CurrentCooling / Heating4,9 / 4,8A
    Rated Power CurrentCooling / Heating6,0A
    Air FlowOutdoor Unit1800m3 / h
    Sound Pressure Level at 1 mOutdoor Unit48dB(A)
    Sound Power LevelOutdoor unit56dB(A)
    Refrigerant / Charge / Eq. CO2R32 / 0,57 / 0,38type / kg / t
    Additional Refrigerant16g / m
    Refrigerant Liquid PipeDiameter1/4 / 6,4inch / mm
    Refrigerant Gas PipeDiameter3/8 / 9,5inch / mm
    Max pipe length without additional refrigerant5m
    Maximum overall length of piping30m
    Max. Elevation15m
    Dimension (w x h x d)Outdoor Unit675 × 553 × 285mm
    Package (w x h x d)Outdoor Unit794 × 605 × 376mm
    Net / Gross WeightOutdoor Unit24,5 / 27,0kg
    Operating Temperature RangeCooling– 20 ~ 52°C
    Operating Temperature RangeHeating– 20 ~ 24°C
    CapacityCooling / Heating5,3 / 5,8kW
    Power SupplyInto Outdoor Unit220–240 / 1 / 50/60V / Ph / Hz
    Power InputCooling / Heating1,56 / 1,47kW
    Rated Power InputCooling / Heating1,9kW
    Power CurrentCooling / Heating7,5 / 7,0A
    Rated Power CurrentCooling / Heating9,5A
    Air FlowOutdoor Unit2200m3 / h
    Sound Pressure Level at 1 mOutdoor Unit52dB(A)
    Sound Power LevelOutdoor unit65dB(A)
    Refrigerant / Charge / Eq. CO2R32 / 0,85 / 0,57type / kg / t
    Additional Refrigerant16g / m
    Refrigerant Liquid PipeDiameter1/4 / 6,4inch / mm
    Refrigerant Gas PipeDiameter1/2 / 12,7inch / mm
    Max pipe length without additional refrigerant5m
    Maximum overall length of piping30m
    Max. Elevation20m
    Dimension (w x h x d)Outdoor Unit745 × 555 × 300mm
    Package (w x h x d)Outdoor Unit872 × 609 × 398mm
    Net / Gross WeightOutdoor Unit30,5 / 33,0kg
    Operating Temperature RangeCooling– 20 ~ 52°C
    Operating Temperature RangeHeating– 20 ~ 24°C
    CapacityCooling / Heating7,1 / 8,0kW
    Power SupplyInto Outdoor Unit220–240 / 1 / 50/60V / Ph / Hz
    Power InputCooling / Heating2,03 / 2,00kW
    Rated Power InputCooling / Heating2,80kW
    Power CurrentCooling / Heating9,7 / 9,6A
    Rated Power CurrentCooling / Heating14,0A
    Air FlowOutdoor Unit3600m3 / h
    Sound Pressure Level at 1 mOutdoor Unit55dB(A)
    Sound Power LevelOutdoor unit69dB(A)
    Refrigerant / Charge / Eq. CO2R32 / 1,50 / 1,01type / kg / t
    Additional Refrigerant20g / m
    Refrigerant Liquid PipeDiameter3/8 / 9,5inch / mm
    Refrigerant Gas PipeDiameter5/8 / 15,9inch / mm
    Max pipe length without additional refrigerant5m
    Maximum overall length of piping30m
    Max. Elevation20m
    Dimension (w x h x d)Outdoor Unit889 × 660 × 340mm
    Package (w x h x d)Outdoor Unit1032 × 730 × 456mm
    Net / Gross WeightOutdoor Unit41,5 / 45,0kg
    Operating Temperature RangeCooling– 20 ~ 52°C
    Operating Temperature RangeHeating– 20 ~ 24°C

     

    CapacityCooling / Heating8,5 / 8,8kW
    Power SupplyInto Outdoor Unit220–240 / 1 / 50/60V / Ph / Hz
    Power InputCooling / Heating2,50 / 2,25kW
    Rated Power InputCooling / Heating3,3kW
    Power CurrentCooling / Heating11,4 / 10,3A
    Rated Power CurrentCooling / Heating15,0A
    Air FlowOutdoor Unit3600m3 / h
    Sound Pressure Level at 1 mOutdoor Unit57dB(A)
    Sound Power LevelOutdoor unit70dB(A)
    Refrigerant / Charge / Eq. CO2R32 / 1,50 / 1,01type / kg / t
    Additional Refrigerant20g / m
    Refrigerant Liquid PipeDiameter3/8 / 9,5inch / mm
    Refrigerant Gas PipeDiameter5/8 / 15,9inch / mm
    Max pipe length without additional refrigerant5m
    Maximum overall length of piping30m
    Max. Elevation25m
    Dimension (w x h x d)Outdoor Unit889 × 660 × 340mm
    Package (w x h x d)Outdoor Unit1032 × 730 × 456mm
    Net / Gross WeightOutdoor Unit46,0 / 50,0kg
    Operating Temperature RangeCooling– 20 ~ 52°C
    Operating Temperature RangeHeating– 20 ~ 24°C
    CapacityCooling / Heating10,0 / 11,5kW
    Power SupplyInto Outdoor Unit220–240 / 1 / 50/60V / Ph / Hz
    Power InputCooling / Heating3,10 / 2,95kW
    Rated Power InputCooling / Heating4,70kW
    Power CurrentCooling / Heating14,8 / 14,1A
    Rated Power CurrentCooling / Heating21,0A
    Air FlowOutdoor Unit4800m3 / h
    Sound Pressure Level at 1 mOutdoor Unit57dB(A)
    Sound Power LevelOutdoor unit70dB(A)
    Refrigerant / Charge / Eq. CO2R32 / 2,10 / 1,42type / kg / t
    Additional Refrigerant20g / m
    Refrigerant Liquid PipeDiameter3/8 / 9,5inch / mm
    Refrigerant Gas PipeDiameter5/8 / 15,9inch / mm
    Max pipe length without additional refrigerant5m
    Maximum overall length of piping75m
    Max. Elevation30m
    Dimension (w x h x d)Outdoor Unit940 × 820 × 370mm
    Package (w x h x d)Outdoor Unit1093 × 885 × 497mm
    Net / Gross WeightOutdoor Unit65,0 / 72,0kg
    Operating Temperature RangeCooling– 20 ~ 52°C
    Operating Temperature RangeHeating– 20 ~ 24°C

     

    CapacityCooling / Heating10,0 / 11,5kW
    Power SupplyInto Outdoor Unit380–415 / 3 / 50/60V / Ph / Hz
    Power InputCooling / Heating3,10 / 2,95kW
    Rated Power InputCooling / Heating4,40kW
    Power CurrentCooling / Heating4,9 / 4,7A
    Rated Power CurrentCooling / Heating7,0A
    Air FlowOutdoor Unit4800m3 / h
    Sound Pressure Level at 1 mOutdoor Unit57dB(A)
    Sound Power LevelOutdoor unit70dB(A)
    Refrigerant / Charge / Eq. CO2R32 / 2,10 / 1,42type / kg / t
    Additional Refrigerant20g / m
    Refrigerant Liquid PipeDiameter3/8 / 9,5inch / mm
    Refrigerant Gas PipeDiameter5/8 / 15,9inch / mm
    Max pipe length without additional refrigerant5m
    Maximum overall length of piping75m
    Max. Elevation30m
    Dimension (w x h x d)Outdoor Unit940 × 820 × 370mm
    Package (w x h x d)Outdoor Unit1093 × 885 × 497mm
    Net / Gross WeightOutdoor Unit75,0 / 82,0kg
    Operating Temperature RangeCooling– 20 ~ 52°C
    Operating Temperature RangeHeating– 20 ~ 24°C
    CapacityCooling / Heating12,1 / 13,5kW
    Power SupplyInto Outdoor Unit380–415 / 3 / 50/60V / Ph / Hz
    Power InputCooling / Heating3,90 / 3,97kW
    Rated Power InputCooling / Heating5,20kW
    Power CurrentCooling / Heating6,2 / 6,3A
    Rated Power CurrentCooling / Heating9,0A
    Air FlowOutdoor Unit5200m3 / h
    Sound Pressure Level at 1 mOutdoor Unit58dB(A)
    Sound Power LevelOutdoor unit73dB(A)
    Refrigerant / Charge / Eq. CO2R32 / 2,25 / 1,52type / kg / t
    Additional Refrigerant20g / m
    Refrigerant Liquid PipeDiameter3/8 / 9,5inch / mm
    Refrigerant Gas PipeDiameter5/8 / 15,9inch / mm
    Max pipe length without additional refrigerant5m
    Maximum overall length of piping75m
    Max. Elevation30m
    Dimension (w x h x d)Outdoor Unit940 × 820 × 370mm
    Package (w x h x d)Outdoor Unit1093 × 885 × 497mm
    Net / Gross WeightOutdoor Unit76,0 / 83,0kg
    Operating Temperature RangeCooling– 20 ~ 52°C
    Operating Temperature RangeHeating– 20 ~ 24°C

     

    CapacityCooling / Heating13,4 / 15,5kW
    Power SupplyInto Outdoor Unit380–415 / 1 / 50/60V / Ph / Hz
    Power InputCooling / Heating4,60 / 4,70kW
    Rated Power InputCooling / Heating5,60kW
    Power CurrentCooling / Heating7,0 / 7,1A
    Rated Power CurrentCooling / Heating11,0A
    Air FlowOutdoor Unit5200m3 / h
    Sound Pressure Level at 1 mOutdoor Unit59dB(A)
    Sound Power LevelOutdoor unit75dB(A)
    Refrigerant / Charge / Eq. CO2R32 / 2,80 / 1,89type / kg / t
    Additional Refrigerant35g / m
    Refrigerant Liquid PipeDiameter3/8 / 9,5inch / mm
    Refrigerant Gas PipeDiameter5/8 / 15,9inch / mm
    Max pipe length without additional refrigerant7,5m
    Maximum overall length of piping75m
    Max. Elevation30m
    Dimension (w x h x d)Outdoor Unit940 × 820 × 370mm
    Package (w x h x d)Outdoor Unit1093 × 885 × 497mm
    Net / Gross WeightOutdoor Unit81,0 / 88,0kg
    Operating Temperature RangeCooling– 20 ~ 52°C
    Operating Temperature RangeHeating– 20 ~ 24°C
    CapacityCooling / Heating16,0 / 17,0kW
    Power SupplyInto Outdoor Unit380–415 / 3 / 50/60V / Ph / Hz
    Power InputCooling / Heating5,40 / 5,70kW
    Rated Power InputCooling / Heating6,80kW
    Power CurrentCooling / Heating9,2 / 9,7A
    Rated Power CurrentCooling / Heating12,0A
    Air FlowOutdoor Unit5500m3 / h
    Sound Pressure Level at 1 mOutdoor Unit60dB(A)
    Sound Power LevelOutdoor unit75dB(A)
    Refrigerant / Charge / Eq. CO2R32 / 3,50 / 2,36type / kg / t
    Additional Refrigerant35g / m
    Refrigerant Liquid PipeDiameter3/8 / 9,5inch / mm
    Refrigerant Gas PipeDiameter5/8 / 15,9inch / mm
    Max pipe length without additional refrigerant7,5m
    Maximum overall length of piping75m
    Max. Elevation30m
    Dimension (w x h x d)Outdoor Unit990 × 960 × 370mm
    Package (w x h x d)Outdoor Unit1153 × 1110 × 478mm
    Net / Gross WeightOutdoor Unit94,0 / 103,0kg
    Operating Temperature RangeCooling– 20 ~ 52°C
    Operating Temperature RangeHeating– 20 ~ 24°C