Capacity | Cooling / Heating | 3,5 / 4 | kW |
Power Supply | Into Indoor Unit | 220–240 / 1 / 50–60 | V / Ph / Hz |
Energy Class | Cooling / Heating | A++ / A+ | – |
Pdesign | Cooling / Heating | 3,5 / 3,0 | kW |
SEER / SCOP | – | 6,5 / 4,0 | W / W |
Annual Electricity Consumption | Cooling / Heating | 189 / 1050 | kWh |
Air Flow | Indoor Unit | 600 / 550 / 500 / 400 | m3 / h |
Sound Pressure Level at 1,4 m | – | 35 / 33 / 32 / 30 | dB(A) |
Sound Power Level | Indoor unit | 56 / – / – / – | dB(A) |
External Static Pressure | Min.–Max. | 0–80 | Pa |
Refrigerant / Charge / Eq. CO2 | – | R32 / – / – | type / kg / t |
Refrigerant Liquid Pipe | Diameter | 1/4 / 6,4 | inch / mm |
Refrigerant Gas Pipe | Diameter | 3/8 / 9,5 | inch / mm |
Dimension (w x h x d) | Indoor Unit | 700 × 450 × 200 | mm |
Package (w x h x d) | Indoor Unit | 1008 × 568 × 275 | mm |
Net / Gross Weight | Indoor Unit | 18,0 / 22,0 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Capacity | Cooling / Heating | 5,3 / 5,6 | kW |
Power Supply | Into Indoor Unit | 220–240 / 1 / 50–60 | V / Ph / Hz |
Energy Class | Cooling / Heating | A++ / A+ | – |
Pdesign | Cooling / Heating | 5,3 / 3,9 | kW |
SEER / SCOP | – | 6,3 / 4,0 | W / W |
Annual Electricity Consumption | Cooling / Heating | 294 / 1365 | kWh |
Air Flow | Indoor Unit | 900 / 800 / 700 / 600 | m3 / h |
Sound Pressure Level at 1,4 m | – | 36 / 35 / 33 / 31 | dB(A) |
Sound Power Level | Indoor unit | 59 / – / – / – | dB(A) |
External Static Pressure | Min.–Max. | 0–80 | Pa |
Refrigerant / Charge / Eq. CO2 | – | R32 / – / – | type / kg / t |
Refrigerant Liquid Pipe | Diameter | 1/4 / 6,4 | inch / mm |
Refrigerant Gas Pipe | Diameter | 1/2 / 12,7 | inch / mm |
Dimension (w x h x d) | Indoor Unit | 1000 × 450 × 200 | mm |
Package (w x h x d) | Indoor Unit | 1308 × 568 × 275 | mm |
Net / Gross Weight | Indoor Unit | 24,0 / 29,0 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Capacity | Cooling / Heating | 7,1 / 8,0 | kW |
Power Supply | Into Indoor Unit | 220–240 / 1 / 50–60 | V / Ph / Hz |
Energy Class | Cooling / Heating | A++ / A+ | – |
Pdesign | Cooling / Heating | 7,1 / 4,7 | kW |
SEER / SCOP | – | 6,6 / 4,1 | W / W |
Annual Electricity Consumption | Cooling / Heating | 377 / 1605 | kWh |
Air Flow | Indoor Unit | 1100 / 1000 / 900 / 800 | m3 / h |
Sound Pressure Level at 1,4 m | – | 37 / 35 / 33 / 31 | dB(A) |
Sound Power Level | Indoor unit | 58 / – / – / – | dB(A) |
External Static Pressure | Min.–Max. | 0–160 | Pa |
Refrigerant / Charge / Eq. CO2 | – | R32 / – / – | type / kg / t |
Refrigerant Liquid Pipe | Diameter | 3/8 / 9,5 | inch / mm |
Refrigerant Gas Pipe | Diameter | 5/8 / 15,9 | inch / mm |
Dimension (w x h x d) | Indoor Unit | 900 × 655 × 260 | mm |
Package (w x h x d) | Indoor Unit | 1115 × 772 × 320 | mm |
Net / Gross Weight | Indoor Unit | 29,5 / 33,5 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Capacity | Cooling / Heating | 8,5 / 8,8 | kW |
Power Supply | Into Indoor Unit | 220–240 / 1 / 50–60 | V / Ph / Hz |
Energy Class | Cooling / Heating | A++ / A+ | – |
Pdesign | Cooling / Heating | 8,5 / 6,0 | kW |
SEER / SCOP | – | 6,4 / 4,1 | W / W |
Annual Electricity Consumption | Cooling / Heating | 465 / 2049 | kWh |
Air Flow | Indoor Unit | 1400 / 1300 / 1100 / 1000 | m3 / h |
Sound Pressure Level at 1,4 m | – | 43 / 41 / 39 / 37 | dB(A) |
Sound Power Level | Indoor unit | 65 / – / – / – | dB(A) |
External Static Pressure | Min.–Max. | 0–160 | Pa |
Refrigerant / Charge / Eq. CO2 | – | R32 / – / – | type / kg / t |
Refrigerant Liquid Pipe | Diameter | 3/8 / 9,5 | inch / mm |
Refrigerant Gas Pipe | Diameter | 5/8 / 15,9 | inch / mm |
Dimension (w x h x d) | Indoor Unit | 900 × 655 × 260 | mm |
Package (w x h x d) | Indoor Unit | 1115 × 772 × 320 | mm |
Net / Gross Weight | Indoor Unit | 29,5 / 33,5 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Capacity | Cooling / Heating | 10,0 / 11,5 | kW |
Power Supply | Into Indoor Unit | 220–240 / 1 / 50–60 | V / Ph / Hz |
Energy Class | Cooling / Heating | A++ / A+ | – |
Pdesign | Cooling / Heating | 10,5 / 7,0 | kW |
SEER / SCOP | – | 6,4 / 4,2 | W / W |
Annual Electricity Consumption | Cooling / Heating | 574 / 2333 | kWh |
Air Flow | Indoor Unit | 1700 / 1600 / 1400 / 1200 | m3 / h |
Sound Pressure Level at 1,4 m | – | 39 / 38 / 37 / 36 | dB(A) |
Sound Power Level | Indoor unit | 62 / – / – / – | dB(A) |
External Static Pressure | Min.–Max. | 0–160 | Pa |
Refrigerant / Charge / Eq. CO2 | – | R32 / – / – | type / kg / t |
Refrigerant Liquid Pipe | Diameter | 3/8 / 9,5 | inch / mm |
Refrigerant Gas Pipe | Diameter | 5/8 / 15,9 | inch / mm |
Dimension (w x h x d) | Indoor Unit | 1340 × 655 × 260 | mm |
Package (w x h x d) | Indoor Unit | 1568 × 770 × 323 | mm |
Net / Gross Weight | Indoor Unit | 43,0 / 49,0 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Capacity | Cooling / Heating | 12,1 / 13,5 | kW |
Power Supply | Into Indoor Unit | 220–240 / 1 / 50–60 | V / Ph / Hz |
Energy Class | Cooling / Heating | A++ / A+ | – |
SEER / SCOP | – | 6,1 / 4,1 | W / W |
Air Flow | Indoor Unit | 2000 / 1800 / 1600 / 1400 | m3 / h |
Sound Pressure Level at 1,4 m | – | 43 / 42 / 41 / 40 | dB(A) |
Sound Power Level | Indoor unit | 66 / – / – / – | dB(A) |
External Static Pressure | Min.–Max. | 0–160 | Pa |
Refrigerant / Charge / Eq. CO2 | – | R32 / – / – | type / kg / t |
Refrigerant Liquid Pipe | Diameter | 3/8 / 9,5 | inch / mm |
Refrigerant Gas Pipe | Diameter | 5/8 / 15,9 | inch / mm |
Dimension (w x h x d) | Indoor Unit | 1340 × 655 × 260 | mm |
Package (w x h x d) | Indoor Unit | 1568 × 770 × 323 | mm |
Net / Gross Weight | Indoor Unit | 43,0 / 49,0 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Capacity | Cooling / Heating | 13,4 / 15,5 | kW |
Power Supply | Into Indoor Unit | 220–240 / 1 / 50–60 | V / Ph / Hz |
Energy Class | Cooling / Heating | A++ / A+ | – |
SEER / SCOP | – | 6,1 / 4,0 | W / W |
Air Flow | Indoor Unit | 2300 / 2100 / 1800 / 1500 | m3 / h |
Sound Pressure Level at 1,4 m | – | 43 / 42 / 40 / 38 | dB(A) |
Sound Power Level | Indoor unit | 67 / – / – / – | dB(A) |
External Static Pressure | Min.–Max. | 0–200 | Pa |
Refrigerant / Charge / Eq. CO2 | – | R32 / – / – | type / kg / t |
Refrigerant Liquid Pipe | Diameter | 3/8 / 9,5 | inch / mm |
Refrigerant Gas Pipe | Diameter | 5/8 / 15,9 | inch / mm |
Dimension (w x h x d) | Indoor Unit | 1400 × 700 × 300 | mm |
Package (w x h x d) | Indoor Unit | 1601 × 813 × 365 | mm |
Net / Gross Weight | Indoor Unit | 52,0 / 58,0 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Capacity | Cooling / Heating | 16,0 / 17,0 | kW |
Power Supply | Into Indoor Unit | 220–240 / 1 / 50–60 | V / Ph / Hz |
Energy Class | Cooling / Heating | A++ / A+ | – |
SEER / SCOP | – | 6,1 / 4,0 | W / W |
Air Flow | Indoor Unit | 2600 / 2300 / 2000 / 1700 | m3 / h |
Sound Pressure Level at 1,4 m | – | 46 / 44 / 42 / 40 | dB(A) |
Sound Power Level | Indoor unit | 70 / – / – / – | dB(A) |
External Static Pressure | Min.–Max. | 0–200 | Pa |
Refrigerant / Charge / Eq. CO2 | – | R32 / – / – | type / kg / t |
Refrigerant Liquid Pipe | Diameter | 3/8 / 9,5 | inch / mm |
Refrigerant Gas Pipe | Diameter | 5/8 / 15,9 | inch / mm |
Dimension (w x h x d) | Indoor Unit | 1400 × 700 × 300 | mm |
Package (w x h x d) | Indoor Unit | 1601 × 813 × 365 | mm |
Net / Gross Weight | Indoor Unit | 55,0 / 62,0 | kg |
Set Temperature range | – | 16 ~ 30 | °C |