Capacity | Cooling / Heating | 2,7 (0,8–3,8) / 3,0 (0,9–4,2) | kW |
Power Supply | Into Indoor Unit | 220–240 / 1 / 50 | V / Ph / Hz |
Air Flow | Indoor Unit | 610 / 570 / 540 / 470 / 440 / 420 / 390 | m3 / h |
Sound Pressure Level at 1 m | Indoor Unit | 38 / 36 / 34 / 31 / 29 / 27 / 25 | dB(A) |
Sound Power Level | Indoor unit | 56 / 48 / 46 / 43 / 41 / 39 / 37 | dB(A) |
Dehumidifying Volume | – | 0,8 | l / h |
Refrigerant / Charge / Eq. CO2 | – | R32 / – / – | type / kg / t |
Refrigerant Liquid Pipe | Diameter | 1/4 / 6 | inch / mm |
Refrigerant Gas Pipe | Diameter | 3/8 / 9,5 | inch / mm |
Dimension (w x h x d) | Indoor Unit | 889 × 294 × 212 | mm |
Package (w x h x d) | Indoor Unit | 940 × 365 × 284 | mm |
Net / Gross Weight | Indoor Unit | 11,0 / 13,0 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Capacity | Cooling / Heating | 3,5 (1,0–3,8) / 3,8 (0,9–4,7) | kW |
Power Supply | Into Indoor Unit | 220–240 / 1 / 50 | V / Ph / Hz |
Air Flow | Indoor Unit | 700 / 650 / 600 / 540 / 480 / 420 / 360 | m3 / h |
Sound Pressure Level at 1 m | Indoor Unit | 42 / 38 / 35 / 32 / 29 / 27 / 25 | dB(A) |
Sound Power Level | Indoor unit | 57 / 50 / 47 / 44 / 41 / 39 / 37 | dB(A) |
Dehumidifying Volume | – | 1,4 | l / h |
Refrigerant / Charge / Eq. CO2 | – | R32 / – / – | type / kg / t |
Refrigerant Liquid Pipe | Diameter | 1/4 / 6 | inch / mm |
Refrigerant Gas Pipe | Diameter | 3/8 / 9,5 | inch / mm |
Dimension (w x h x d) | Indoor Unit | 889 × 294 × 212 | mm |
Package (w x h x d) | Indoor Unit | 940 × 365 × 284 | mm |
Net / Gross Weight | Indoor Unit | 11,0 / 13,0 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Capacity | Cooling / Heating | 5,2 (1,0–6,1) / 5,3 (1,1–6,0) | kW |
Power Supply | Into Indoor Unit | 220–240 / 1 / 50 | V / Ph / Hz |
Air Flow | Indoor Unit | 800 / 720 / 650 / 610 / 570 / 520 / 470 | m3 / h |
Sound Pressure Level at 1 m | Indoor Unit | 45 / 43 / 41 / 38 / 36 / 34 / 31 | dB(A) |
Sound Power Level | Indoor unit | 59 / 57 / 55 / 52 / 49 / 48 / 45 | dB(A) |
Dehumidifying Volume | – | 1,8 | l / h |
Refrigerant / Charge / Eq. CO2 | – | R32 / – / – | type / kg / t |
Refrigerant Liquid Pipe | Diameter | 1/4 / 6 | inch / mm |
Refrigerant Gas Pipe | Diameter | 1/2 / 12 | inch / mm |
Dimension (w x h x d) | Indoor Unit | 1013 × 307 × 221 | mm |
Package (w x h x d) | Indoor Unit | 1080 × 378 × 315 | mm |
Net / Gross Weight | Indoor Unit | 13,5 / 16,5 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Capacity | Cooling / Heating | 5,3 (1,3–6,6) / 5,6 (1,4–7,5) | kW |
Power Supply | Into Indoor Unit | 220–240 / 1 / 50 | V / Ph / Hz |
Air Flow | Indoor Unit | 850 / 750 / 680 / 610 / 570 / 520 / 460 | m3 / h |
Sound Pressure Level at 1 m | Indoor Unit | 47 / 41 / 39 / 37 / 35 / 32 / 31 / 21 | dB(A) |
Sound Power Level | Indoor unit | 60 / 57 / 55 / 54 / 52 / 50 / 46 / 34 | dB(A) |
Dehumidifying Volume | – | 1,9 | l / h |
Refrigerant / Charge / Eq. CO2 | – | R32 / – / – | type / kg / t |
Refrigerant Liquid Pipe | Diameter | 1/4 / 6 | inch / mm |
Refrigerant Gas Pipe | Diameter | 1/2 / 12 | inch / mm |
Dimension (w x h x d) | Indoor Unit | 1013 × 307 × 221 | mm |
Package (w x h x d) | Indoor Unit | 1060 × 374 × 297 | mm |
Net / Gross Weight | Indoor Unit | 13,5 / 15,5 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Capacity | Cooling / Heating | 7,0 (2,0–8,5) / 7,4 (2,2–9,0) | kW |
Power Supply | Into Indoor Unit | 220–240 / 1 / 50 | V / Ph / Hz |
Air Flow | Indoor Unit | 1250 / 1100 / 1000 / 950 / 900 / 850 / 750 | m3 / h |
Sound Pressure Level at 1 m | Indoor Unit | 48 / 45 / 42 / 39 / 37 / 36 / 33 | dB(A) |
Sound Power Level | Indoor unit | 58 / 55 / 52 / 49 / 47 / 46 / 43 | dB(A) |
Dehumidifying Volume | – | 2,4 | l / h |
Refrigerant / Charge / Eq. CO2 | – | R32 / – / – | type / kg / t |
Refrigerant Liquid Pipe | Diameter | 1/4 / 6 | inch / mm |
Refrigerant Gas Pipe | Diameter | 5/8 / 16 | inch / mm |
Dimension (w x h x d) | Indoor Unit | 1122 × 329 × 247 | mm |
Package (w x h x d) | Indoor Unit | 1177 × 406 × 332 | mm |
Net / Gross Weight | Indoor Unit | 17,5 / 21,0 | kg |
Set Temperature range | – | 16 ~ 30 | °C |
Capacity | Cooling / Heating | 7,1 (2,0–8,9) / 7,8 (1,8–9,5) | kW |
Power Supply | Into Indoor Unit | 220–240 / 1 / 50 | V / Ph / Hz |
Air Flow | Indoor Unit | 1250 / 1100 / 1000 / 950 / 900 / 850 / 800 / 600 | m3 / h |
Sound Pressure Level at 1 m | Indoor Unit | 50 / 47 / 43 / 41 / 40 / 36 / 35 / 27 | dB(A) |
Sound Power Level | Indoor unit | 64 / 59 / 56 / 55 / 53 / 51 / 48 / 42 | dB(A) |
Dehumidifying Volume | – | 2,4 | l / h |
Refrigerant / Charge / Eq. CO2 | – | R32 / – / – | type / kg / t |
Refrigerant Liquid Pipe | Diameter | 1/4 / 6 | inch / mm |
Refrigerant Gas Pipe | Diameter | 5/8 / 16 | inch / mm |
Dimension (w x h x d) | Indoor Unit | 1122 × 329 × 247 | mm |
Package (w x h x d) | Indoor Unit | 1177 × 406 × 332 | mm |
Net / Gross Weight | Indoor Unit | 16,5 / 19,5 | kg |
Set Temperature range | – | 16 ~ 30 | °C |